The rule this planner uses
Daily watt-hours size the battery. The largest AC load at one moment sizes the inverter. A short cooking session barely moves the day, and it can still set the inverter. How the day is added up.
This planner only lands on 1,000 W, 2,000 W, or 3,000 W.
- Nothing listed on the AC side, and no air conditioner running from the battery, stays at 1,000 W. A larger day does not raise that on its own.
- A listed load uses the higher of the day's class and the load. When the load still fits in 2,000 W with room, the plan stays at 2,000 W.
- Induction is a heavy AC-side load. When the day asks for 3,000 W, the plan steps up, even though the cooktop itself is under 2,000 W. If the loads together pass 3,000 W, the plan stays there.
The screening figures are an induction cooktop at 1,800 W, a workstation at 150 W for one laptop and a monitor, and a 120 V rooftop air conditioner at 1,450 W. A chosen unit replaces its figure. A DC rooftop unit is not one of these AC loads.
Worked sample (planning estimates)
One van, three load lists. The same two-adult longer trip as the battery page: a Sprinter 170 high roof, spring through fall, some nights away from hookups, 12 V, in this planner's North America catalog. The first two rows cook on propane. The last row is induction. These are planning estimates, the same math first numbers uses.
| Trip | AC loads listed | Daily energy | Inverter class |
|---|---|---|---|
| Propane, no desk | Nothing listed | 1,750 Wh | 1,000 W |
| Propane, remote work | Workstation, 150 W | 3,083 Wh | 2,000 W |
| Induction, remote work | 1,950 W listed | 3,883 Wh | 3,000 W |
The middle row is the remote-work day on the battery page. That page lists the same 2,000 W class.
A 3,000 W class unit in the example plan is the Victron MultiPlus 12/3000/120 Inverter/Charger. The MultiPlus 2 kVA and 3 kVA 120 V datasheet lists continuous output power at 25°C as 2,400 W and peak power as 6,000 W. Those are that model's datasheet figures. The 1,000 W, 2,000 W, and 3,000 W labels on this page are the planner's buyable classes.
What it depends on
- What is on at once. The inverter follows the largest AC moment, not the battery amp-hours. Daily watt-hours and the battery step are the other half. Solar follows the day. Charging while you drive is the DC-DC charger.
- Induction without the desk. On this same trip, induction and no workstation is 2,000 W. The cooktop screens at 1,800 W and the day is 2,550 Wh. The 3,000 W row above is the cooktop plus the workstation, not the cooktop by itself.
- A larger day with a small AC load. The same 150 W workstation on a hot summer day is a 3,583 Wh day, and the inverter is 2,000 W. The load listed is 150 W, which still fits in that class with room.
- Stacking big loads. Induction, the workstation, and a 120 V rooftop air conditioner on this trip list 3,400 W together. The plan stays at 3,000 W and notes that the loads together pass that class. It says not to run the cooktop and the air conditioner at the same time.
- A DC rooftop unit. It is not an inverter load. On this same trip, with that unit running from the battery and nothing else listed on the AC side, the plan is 3,000 W for a 3,750 Wh day. The planner keeps the day's class. The propane trip with no air conditioner stays at 1,000 W.
- System voltage. The same induction work day at 48 V is 3,000 W, the same class as 12 V. System voltage changes the current. It does not change this watt class in this sample.
First numbers states the inverter watts next to the battery and the solar for the van and the loads you enter.
When to bring in a professional
The class is yours to choose from. The cables from the battery to the inverter, the main fuse, and anything on 120 V AC or shore power carry high current. Have a qualified electrician or RV/marine electrical tech design or check that part before you connect it. Where a planning estimate stops and that design starts is planning estimate versus professional design.